A high output impedance cmos current driver for bioimpedance measurements

Bioelectrical impedance measurements can be used in a wide range of clinical applications for monitoring and tissue characterization. Hi, i am trying to develop a system for bioimpedance measurement of the skin. Bioimpedance measurements are mainly performed in two different configurations, depending on the number of electrodes 33, 45, 68, 107, 1. The frequency generator allows an external complex impedance to be excited with a known frequency. Fundamentals, recent advances, and future challenges in. A bioimpedance sensor is a circuit attached to ecglike electrodes on the skin. A floating wideband current source for electrical impedance.

An improved wideband cmos current driver for bioimpedance. Important features for current drivers are high output impedance, low phase delay. High power cmos current driver with accurate transconductance for electrical impedance. Bioimpedance is about the electrical properties of your body or other biomaterials, e. The presented system goal is to achieve a digital bioimpedance system implementation in high frequency bioimpedance computing application. Introduction he impedance is an useful parameter for determining the properties of biological materials because these are conductives 1 and impedance measurement represents a noninvasive technique. Oct 03, 2014 furthermore, bioimpedance measurements are acknowledged for being noninvasive and painless with no known hazards. A current driver should have high output impedance with respect to load, so that all the current gets transferred to the load, and not shunted away. It uses an improved regulated cascode to enhance output impedance, enabling accurate measurements of transfer impedances at low and high frequencies.

In this paper, we first focus on recent studies on designed eit current sources, and after that, a practical design of a floatingload high output impedance current sourceoperating over a wide frequency bandwill be proposed in detail. These signals are generated through the dds compiler 4. I am trying to match a 50 ohm coax cable impedance with a series impedance at the driver. Bioimpedance measurement applications need current drivers with high output impedance and stable current injection in the frequencies from dc to about 10 mhz. Analog integrated current drivers for bioimpedance applications. They are capable of extracting complex impedance vectors at a single test condition, or while sweeping source parameters like frequency, amplitude, and dc bias. For example, an output impedance of 1 mw for a load of 1 kw will provide 0. Electrical bioimpedance for cardiac output measurement. In the case of eit, the current driver is required to have a large output. In order to measure bioimpedance, current stimulation is generally. Constantinou l, triantis if, bayford r, demosthenous a. A high output impedance cmos current driver for bioimpedance. Rule 2, the output impedance varies with power supply voltage. Current drivers are suitable for bioimpedance measurements applications.

City research online highpower cmos current driver with. This dds has three output signals namely the injected current to tissue and two reference signals. The response signal from the impedance is sampled by the onboard adc and a disc. Such applications require wideband typically 1 mhz accurate ac current drivers with high output impedance and low distortion. Rule 3, the output impedance will vary from part to part. Nazanin neshatvar, peter langlois, richard bayford and. This paper presents an improved current driver based on a pair of balanced operational. Bioimpedance measurement of the skin contact impedance. Furthermore, bioimpedance measurements are acknowledged for being noninvasive and painless with no known hazards. How to determine the output impedance of cmos gates.

The ad5933 is a high precision impedance converter system solution that combines an onboard frequency generator with a 12bit, 1 msps, analogtodigital converter adc. The term bioimpedance is commonly used to refer to the impedance of the human body or a part of it. Low power current sources for bioimpedance measurements. Triantis was born in geneva, switzerland in 1976 and received his basic education in ioannina, greece. A current driver should have high output impedance with respect to load. The measurement of this parameter was employed in multiple fields, ranging from the assessment of body composition or of intrathoracic fluid status, to respiration, cardiac output and peripheral blood flow monitoring. I have follow up questions dealing with reflection etc, but will post that in a separate thread. This paper presents an integrated current driver that fulfills these requirements.

The presented system goal is to achieve a digital bio impedance system implementation in high frequency bio impedance computing application. Design of current sources for load common mode optimization. Dec 19, 2018 the output current difference between the source and sink sees the output impedance of the current sources, creating high common mode voltage and reducing output swing. In this paper we present an integrated current driver which meets. In the case of eit, the current driver is required to have a large output impedance to guarantee high current accuracy over a wide range of load impedance values. Programmable digital bioimpedance measurement system. The accuracy of single port vna measurements in the 1k ohm impedance range is quite good and is acceptable in the 10k ohm range if care is taken when making the measurements. A high output impedance current source for wideband. Electrical bioimpedance for cardiac output measurement page 3 of 7 unitedhealthcare oxford clinical policy effective 09012019 19962019, oxford health plans, llc heart disease or heart failure in a prospective cohort study, taylor et al. An independent reference voltage is used in order to. High power cmos current driver with accurate transconductance for electrical impedance tomography. Design of an integrated bioimpedance measurement system for.

This paper presents a new current source, which achieves high output impedance 1 m. Zaid hamed chief technical officer epiguard linkedin. Highpower cmos current driver with accurate transconductance. This research presents a field programmable gate array fpga based high accuracy broadband bioimpedance measurement system bms for time resolved bioimpedance measurements.

Highpower cmos current driver with accurate transconductance for electrical impedance tomography. Simulation results including montecarlo analysis are presented to show the operation of the circuit. A programmable low power current source for bioimpedance. A wideband lowdistortion cmos current driver for tissue. An improved cmos current driver for electrical impedance tomography. This current driver circuits are introduced based on a transconductance and provide accurate current output. The use of fully differential amplifiers allows the input voltage to be connected to the same input at both sides, minimizing the difference between input impedances. Important features for current drivers are high output impedance, low phase delay, and. The reason behind the higher the value of r f the higher the output impedance, is that r f acts like a current divider. The output current difference between the source and sink sees the output impedance of the current sources, creating high common mode voltage and reducing output swing. Wideband fully differential current driver with optimized. In 5, an integrated current driver was introduced using standard 0. High output impedance currentconveyor oscillator for. The differential howland current source with high signal to.

Bioimpedance measurements are performed in a wide range of frequencies 100hz to 1mhz as physiological tissue information is scattered throughout this frequency band. A precision transconductance for electrical impedance. This research presents a field programmable gate array fpga based high accuracy broadband bioimpedance measurement system bms. A high output impedance cmos current driver for bioimpedance measurements. Current driver are require accurate output current value. I drive quite a high voltage 34v differentially 68v at my electrodes and measure the resulting current. Impedance measurement instruments are employed for development, characterization, and test of sensors, electronic components, electrochemical cells, and materials. Measurement of cardiac output using bioimpedance methd.

Pdf a wideband cmos current driver for bioimpedance. If left floating, it will tend to float to a voltage in between vdd and ground, right in the middle of the highlow thresholds, causing erroneous triggering. Highsensitivity bioimpedance measurement analog front end on. Bioimpedance measurement is defined as the study of biological. An improved cmos current driver for electrical impedance. I will sweep from 1khz to 1mhz, but use 100khz for most of my tests. The development of a low power current source without using an external voltage generator might be very attractive for measuring cell impedance at the electrode site and for designing battery powered bioimpedance systems. Most often, the gates have lower resistance in the low state.

When connecting the loadintheloop to the current conveyor, the output impedance at 1 mhz increases slightly but remains. Current drivers are fundamental circuits in bioimpedance measurements including electrical impedance tomography eit. Wideband current drivers with high output impedance are essential to maintain high injected current accuracy over a wide range of load impedances. A high accuracy bioimpedance measurement system bms for. In this work a novel programmable, low complexity, high output impedance, high voltage compliance and wideband current source for bioimpedance applications is presented. Bioimpedance is a measure of how well the body impedes electric current flow. As the output impedance of the current source and the input impedance of the voltage amplifier can be very high, the effects of the changes of the contact resistance would be minimal. A wideband cmos current driver for bioimpedance applications with output dc regulation. High performance analog abstract this article gives a brief overview of bioimpedance measurements and discusses the methodology to measure impedance with afe4300, an analog frond end for weight and body composition measurement.

Abstractbioimpedance measurements are performed in a variety of medical applications including cancer detection in tissue. Sep 30, 2010 rule 1, the output impedance for a low state is not necessarily the same as that of a high state. Bioimpedance is a noninvasive measurement method that facilitates body composition analysis, besides being indicative of many other health parameters. This paper presents a wideband fully differential current driver architecture suitable for bioimpedance measurements. Advances in bioimpedance measurement applications need current drivers with high output impedance in the frequencies ranging from dc to a number of mhz. The current driver architecture maximizes the output voltage swing. Jun 27, 2016 bioimpedance analysis is a vital tool in both biomedical engineering and life science.

Electrical bioimpedance for cardiac output measurement page 3 of 6 unitedhealthcare oxford clinical policy effective 09012017 19962017, oxford health plans, llc heart disease or heart failure in a nonrandomized controlled trial, taylor et al. Novel cmos integrated current drivers for wideband. Ive been getting some good advice here lately so i thought id try to push my luck with a more applicationspecific question. Abstract bioimpedance is a noninvasive measurement method that facilitates body composition analysis, besides being indicative of many other health parameters. For the heart rate, they dont use an impedance measure thatd be kind of pointless when you have the wonderful, huge ecg electrocardiographic signal. Highsensitivity bioimpedance measurement analog front end. Current sources for bioimpedance measurements are limited by insufficient output impedance above 100 khz.

Rule 1, the output impedance for a low state is not necessarily the same as that of a high state. Wideband fully differential current driver with optimized output. Analog integrated current drivers for bioimpedance. Most meb systems use wideband current sources for injecting current and instrumentation amplifiers for measuring the resultant potential difference. Pdf analog integrated current drivers for bioimpedance. The cmos current driver circuits are portable for high resolution, high frequency image system.

Wideband mirrored current source design based on differential. Bioimpedance measurement is defined as the study of biological tissuecell in. Use the shortest leads possible, calibrate to the ends of the leads with components that. Use of band electrodes faced a lot of criticism due to the noise introduced by them. This paper presents an integrated current driver that ful.

As the impedance is presented as real and imaginary or magnitude and phase. Abstract multifrequency electrical bioimpedance meb has been widely used as a noninvasive technique for characterizing tissues. Pdf bioimpedance measurements are performed in a variety of medical applications. Bioimpedance measurements are based on the injection of small wellknown alternating currents via. Bioimpedance measurements are based on the injection of small wellknown alternating currents via surface. The desirable characteristics for the design of the vccs are a constant current for variable loads and a high output impedance, especially in the case of eit. A low power bioimpedance module for wearable systems. If r f increases, the output impedance increases to around 1. A wideband, cmos current driver for bioimpedance measurement. He received his meng degree from the department of electrical engineering and electronics, umist now part of manchester university in manchester, uk in 2000. Bioimpedance analysis is a vital tool in both biomedical engineering and life science. Highpower cmos current driver with accurate transconductance for. Therefore, the cmos source impedance adds to the resistance of the resistor i believe. Pdf a wideband lowdistortion cmos current driver for tissue.